Special requirements for air purification equipment IEC 60335-2-65, Analysis of the latest version of AS/NZS 60335.2.65 standard requirements
Time:
2025-05-06
Special requirements for air purification equipment - Analysis of the latest versions of IEC 60335-2-65 and AS/NZS 60335.2.65 standard requirements
After the release of the IEC 60335-1:2020 standard, it has gradually been applied in recent years, and the latest standards of the IEC 60335 series of sub standards have also been released, which are used in conjunction with IEC 60335-1:2020. Among them, IEC 60335-2-65:2023 and AS/NZS 60335.2.65:2024 have been published for use.

At present, the version numbers and validity of various certified IEC 60335-2-65 and IEC 60335-1 matching standards can refer to the following table:
1、CB
|
Version |
Standard number | Effectiveness |
|
Old version |
IEC60335-1: 2010+A1:2013+ A2:2016 IEC 60335-2-65: 2002+A1:2008+ |
effective |
| New edition |
IEC60335-1: 2020 IEC 60335-2-65: 2023 |
effective |
2、SAA/RCM
|
Version |
Standard number | Effectiveness |
|
Old version |
AS/NZS60335.1:2020+ AS/NZS 60335.2.65:2015 |
effective |
|
New edition |
AS/NZS60335.1:2022 AS/NZS60335.2.65:2024 |
effective |
3、CE-LVD
|
Version |
Standard number | Effectiveness |
|
Old version |
EN60335-1: 2012+AC:2014+ A11:2014+A13:2017+A1:2019+ A14:2019+A2:2019+A15:2021 EN60335-2-65: 2003+A1:2008+ A11:2012 |
effective |
|
New edition |
No matching standards with EN IEC 60335-1:2023+A11:2023 |
|
4、PSE
| Version | Standard number | Effectiveness |
|
Old version |
J60335-1(H27) J60335-2-65 (2024) |
effective |
| New edition |
There is no matching standard with J60335-1 (2024) |
|
The main changes in the new standard IEC 60335-2-65 and AS/NZS 60335.2.65 are as follows:
1. Scope of application: DC power supply appliances and battery power supply appliances with a voltage not exceeding 480V have been added.
2. Universal standard matching: Used in conjunction with IEC 60335-1:2020.
3. Definition: Air purification equipment adds information to other processing systems, not limited to filtration systems.
4. Nameplate, identification, instruction manual: requirements corresponding to symbol IEC 60417-6040 ultraviolet radiation identification have been added.
5. Normal temperature rise: Add testing methods and limit requirements for touchable surface temperature rise.
6. Structure:
- Add the application of test finger 19.
- Exemption from the requirement for movable and non hazardous moving parts switches for long-term/automatic/remote use of products.
7. Removed requirements and testing for UV resistant materials and UV exposure. But in fact, Clause 32.2 and Annex T in IEC 60335-1:2020 have added corresponding requirements.
Common precautions:
1. Anti UV radiation materials can be selected from glass, ceramics, and metals.
2. Optical radiation needs to be assessed according to IEC/EN 62471.