◉ Introduction to Industrial Water
Industrial water mainly refers to the general term for water used in manufacturing, processing, cooling, air conditioning, washing, boilers, etc., and domestic water for workers in the factory in the industrial production process (or period) by various departments of industrial and mining enterprises.
◉ Scope of Test
(1) Production water testing: water directly used in industrial production is called production water. Manufacturing water includes indirect cooling water, process water, and boiler water.
(2) Indirect cooling water detection: In the industrial production process, in order to ensure that the production equipment can work at normal temperature to absorb or transfer the excess heat of the production equipment, the cooling water used for cooling water (through the heat exchanger wall or equipment Divide it into indirect cooling water.
(3) Process water detection: This part of the water used for manufacturing and processing products in industrial production and related to the manufacturing process is called process water. Process water includes product water, cleaning water, direct cooling water, and other waters.
(4) Product water testing: During the production process, a part of the water used as raw materials for the production of products is called product water (this water is either used as a component of the product, or participates in chemical reactions).
(5) Detection of washing water: In the production process, the water used for washing raw materials and semi-finished products is called washing.
(6) Direct cooling water detection: In the production process, in order to meet the needs of the technological process, the cooling water or semi-finished products that are in direct contact with the product (including direct-flow spray water for temperature and humidity regulation) are called direct cooling water.
(7) Other process water testing
(8) Boiler water testing: The steam required for the process or heating and power generation and the water required for boiler water treatment are collectively referred to as boiler water. Boiler water supply includes boiler feed water and boiler water treatment water.
(9) Boiler feed water detection: The water directly used to generate industrial steam is called boiler feed water. The boiler water supply consists of two parts: one is condensed water obtained from water vapor cooling, and the other is supplemental softened water.
(10) Boiler water treatment water detection: When demineralized water is prepared for the boiler, regeneration is required. Water for projects such as flushing is called boiler water treatment water.
◉ Test Items
(1) Microbial detection: total number of colonies, coliforms, mold, yeast, Salmonella, Shigella, Escherichia coli, Vibrio parahaemolyticus, Staphylococcus aureus, hemolytic streptococcus, gas-producing clips Clostridium cereus, Bacillus cereus, Listeria monocytogenes, Legionella, Vibrio cholerae, Enterobacter sakazakii, Campylobacter jejuni, Pseudomonas aeruginosa, Enterococcus, etc.
Sensory properties: color, turbidity, odor and taste, visible to the naked eye, etc.
(2) Sensory properties: chroma, turbidity, odor and taste, visible to the naked eye, etc.
(3) Physical indicators: PH value, conductivity, total hardness, total dissolved solids, volatile phenol, anionic synthetic detergent, etc.
(4) Comprehensive indicators: oxygen consumption, biochemical oxygen demand, total organic carbon, etc.
(5) Metal elements: beryllium, lead, cadmium, chromium, mercury, thallium, potassium, calcium, sodium, magnesium, phosphorus, iron, arsenic, selenium, zinc, tin, manganese, cobalt, nickel, iodine, vanadium, etc.
(6) Inorganic non-metals: sulfate, chloride, chlorate, chlorite, fluoride, nitrate nitrogen, sulfide, phosphate, boron, ammonia nitrogen, nitrite, iodide, bromate, etc.
(7) Organic substances: benzene, xylene, benzopyrene, bisphenol A, formaldehyde, carbon tetrachloride, chlorodibromomethane, dichloromonobromomethane, trichloroethylene, tetrachloroethylene, bromomethane, phthalic acid Bis(2-ethylhexyl)ester, etc.
◉ Related Standards
"Analytical methods for boiler water and cooling water-Determination of zinc ions-Zinc reagent spectrophotometry" GB/T 10656-2008
"Determination of Silicon in Industrial Circulating Cooling Water and Boiler Water" GB/T 12149-2007
"Determination of Oil Content in Boiler Water and Cooling Water" GB/T 12152-2007
"Boiler Water and Cooling Water Analysis Methods Determination of All Aluminium" GB/T 12154-2008
"Determination of solid matter in industrial circulating cooling water and boiler water" GB/T 14415-2007
"Boiler water and cooling water analysis method Determination of total silicon" GB/T 14417-1993
"Boiler Water and Cooling Water Analysis Methods Determination of Iron" GB/T 14427-2008
"Determination of copper and zinc in industrial circulating cooling water and scale by atomic absorption spectrometry" GB/T 14637-2021
"Determination of potassium and sodium content in industrial circulating cooling water and boiler water" GB/T 14640-2008
"Determination of Fluorine, Chlorine, Phosphate, Nitrite, Nitrate and Sulfate in Industrial Circulating Cooling Water and Boiler Water - Ion Chromatography" GB/T 14642-2009
"Determination of total alkalinity and phenolphthalein alkalinity of industrial circulating cooling water" GB/T 15451-2006
"Determination of Conductivity of Boiler Water and Cooling Water Analysis Method" GB/T 15452-2009
"Determination of Chloride Ion in Industrial Circulating Cooling Water and Boiler Water" GB/T 15453-2008
"Determination of sodium, ammonium, potassium, magnesium and calcium ions in industrial circulating cooling water by ion chromatography" GB/T 15454-1995
"Determination of Chemical Oxygen Demand (CoD) in Industrial Circulating Cooling Water by Potassium Permanganate Method" GB/T15456-2008
"Water Quality of Industrial Boilers" GB/T 1576-2008
"Operation Effect and Monitoring of Industrial Boiler Water Treatment Facilities" GB/T 16811-2018
"Determination of pH in Industrial Circulating Cooling Water and Boiler Water" GB/T 6904-2008
"Boiler water and cooling water analysis methods - water sample collection method" GB/T 6907-2022
"Analytical methods for boiler water and cooling water - Determination of electrical conductivity" GB/T 6908-2018
"Analytical Methods for Boiler Water and Cooling Water - Determination of Hardness" GB/T 6909-2018
"Boiler Water and Cooling Water Analysis Methods Determination of Nitrite" GB/T 6912-2008
"Analytical Methods for Boiler Water and Cooling Water - Determination of Phosphate" GB/T 6913-2008
"Water Quality Requirements for Marine Auxiliary Boilers" GB/T 24947-2010
"Boiler water treatment chemical performance evaluation method - dynamic method" HG/T 3924-2007
"Boiler water (medium) treatment supervision and management rules" TSG G5001-2010
"Boiler water (medium) treatment inspection rules" TSG G5002-2010
◉ Compliance Services
As a professional third-party testing and certification service organization, Jiayu Testing has qualifications such as CMA, CNAS, and occupational health technical service institutions. In the field of environmental testing, it currently has more than 1000 CMA testing parameters, covering water and wastewater, air and exhaust gas, soil and sediment, noise and vibration, and solid waste toxicity identification. The laboratory is built and managed strictly in accordance with standards, equipped with advanced instruments and equipment, and has a professional technical team with superb skills. It has rich industry service experience and strong testing technology capabilities. Based on the principles of objectivity and fairness, it provides authoritative testing reports with legal effect to the society, and provides full chain environmental risk management support for enterprises and regulatory departments. Welcome to contact us at 400-9269-886!