Search : Electronic And Electrical Testing, Safety Testing, Environmental Monitoring

GB 5749-2022 "Sanitary Standard for Drinking Water" implemented on April 1


Time:

2023-04-01

The State Administration of Market Supervision and Administration and the National Standardization Administration approved the release of GB 5749-2022 "Sanitary Standards for Drinking Water" on March 15, 2022, which will be implemented on April 1, 2023.

The State Administration of Market Supervision and Administration and the National Standardization Administration approved the release of GB 5749-2022 "Sanitary Standards for Drinking Water" on March 15, 2022, which will be implemented on April 1, 2023.

The original standard GB5749-2006 "Sanitary Standard for Drinking Water" has been implemented for nearly 15 years since July 1, 2007. The new sanitary standard for drinking water has been issued, and the original standard has been revised. This time, the scope of the standard has been revised, normative references have been updated, terms and definitions such as centralized water supply, small-scale centralized water supply, secondary water supply, factory water, and peripheral water indicators have been improved or added or deleted, as well as editorial changes have been made to the text of some clauses.

 

Water quality indicators

01. Total Index Adjustment

The water quality indicators have been adjusted from 106 items in GB5749-2006 to 97 items. Including: 43 regular indicators and 54 expanded indicators. Add 4 indicators and delete 13 indicators.

 

02. Four new indicators

Index

Limits

Perchloric acid/(mg/L)

0.07

Acetochlor/(mg/L)

0.02

2-Methylisocamphenol/(mg/L)

0.00001

Geosmin/(mg/L)

0.00001

 

03. Delete 13 indicators

The 13 indicators deleted include heat-resistant coliform bacteria, trichloroacetaldehyde, sulfide, cyanogen chloride (calculated by CN -), hexachlorocyclohexane (total), parathion, methyl parathion, lindane, DDT, formaldehyde, 1,1,1-trichloroethane, 1,2-dichlorobenzene, and ethylbenzene.

 

04. Index name change

GB5749-2006 GB5749-2022
Oxygen consumption (CODMn method, calculated as O2) Permanganate index (calculated as O2)
Ammonia nitrogen (calculated by N) Ammonia (calculated by N)
1,2-dichloroethylene 1,2-dichloroethylene (total)

 

05. Index limit change

No.

Indicator Name

GB5749-2006

GB5749-2022

1

Nitrate (calculated as N)/(mg/L)

20 when groundwater source is limited

When small-scale centralized water supply and decentralized water supply are limited by water source and water purification technology, nitrate (calculated as N) shall be 20 mg/L

2

Turbidity (NTU)

3 when water source and purification conditions are limited

When limited by small centralized water supply and decentralized water supply sources and water purification technology, it shall be implemented as per 3

3

Permanganate index (calculated as O2) (mg/L)

Water source limitation: 5mg/L for raw water consumption>6mg/L

3mg/L

4

Free chlorine (mg/L)

(1) Contact time with water: ≥ 30min;

(2) Factory water limit: 4mg/L

(3) Factory water margin: ≥ 0.3mg/L;

(4) Water margin at the end of pipe network 

(1) Contact time with water: ≥ 30min;

(2) Limit value of factory water and tip water: ≤ 2mg/L

(3) Residual amount of factory water: ≥ 0.3mg/L;

(4) Tip water margin: ≥ 0.05mg/L.

5

Boron (mg/L)

0.5

1.0

6

Vinyl chloride (mg/L)

0.005

0.001

7

Trichloroethylene (mg/L)

0.07

0.02

8

Dimethoate (mg/L)

0.08

0.006

 

06. Other changes

1. Added total β The requirement to deduct 40K from the radionuclide analysis and evaluation of radioactive indicators and the applicability of the microcystin-LR indicator;
2. The temporary regulations on water quality indicators and limits for small-scale centralized water supply and decentralized water supply have been deleted;
3. Improve the requirements for the quality of drinking water sources;  
4. Deleted content related to drinking water management.

 

Water quality reference index

01. Total Index Adjustment

The reference indicators for water quality have been adjusted from 28 to 55 in GB5749-2006.

 

02. Add 29 indicators

No.

Index

Limits

1

Vanadium/(mg/L)

0.01

2

HCH (total)/(mg/L)

0.005

3

Parathion/(mg/L)

0.003

4

Methyl parathion/(mg/L)

0.009

5

Lindane/(mg/L)

0.002

6

DDT/(mg/L)

0.001

7

Trichlorfon/(mg/L)

0.05

8

Thiobandam methyl/(mg/L)

0.3

9

Daowenling/(mg/L)

0.3

10

Fluralin/(mg/L)

0.02

11

Metalaxyl/(mg/L)

0.05

12

Xicaojin/(mg/L)

0.03

13

Acephate/(mg/L)

0.08

14

Formaldehyde/(mg/L)

0.9

15

Trichloroacetaldehyde/(mg/L)

0.1

16

Cyanogen chloride (calculated as CN -)/(mg/L)

0.07

17

Nitrosodimethylamine/(mg/L)

0.0001

18

Iodiacetic acid/(mg/L)

0.02

19

1,1,1-Trichloroethane/(mg/L)

2

20

Ethylbenzene/(mg/L)

0.3

21

1,2-Dichlorobenzene/(mg/L)

1

22

Perfluorooctanoic acid/(mg/L)

0.00008

23

Perfluorooctane sulfonic acid/(mg/L)

0.00004

24

Dimethyl disulfide/(mg/L)

0.00003

25

Dimethyl trisulfide/(mg/L)

0.00003

26

Iodide/(mg/L)

0.1

27

Sulfide/(mg/L)

0.02

28

Uranium/(mg/L)

0.03

29

Radium-226/(mg/L)

1

 

03. Delete 2 indicators

The two indicators deleted include 2-methylisocamphenol and soil odor.

 

04. Index name change

GB5749-2006 GB5749-2022
Dibromoethylene 1,2-dibromoethane/(mg/L)
Nitrite Nitrite (calculated as N)/(mg/L)
Asbestos (>10 μ m) Asbestos (fiber>10 μ m) /(10000/L)

 

05. Index limit change

No.

Indicator Name

GB5749-2006

GB5749-2022

1

Petroleum (total)/(mg/L)

0.3

0.05

 

手机官网
手机官网

Wechat Public