The new national standard for noise limits of household appliances (GB/T 19606-2024) covers 19 categories of household appliances and will be officially implemented in September 2026
Time:
2026-09-11
GB/T 19606-2024 "Noise Limits for Household and Similar Electrical Appliances" specifies the noise limits, testing methods, and noise labeling requirements for household and similar electrical appliances, covering 19 major categories of household appliances. The standard specifies the market entry threshold and will officially come into effect on September 1, 2026. Products with excessive noise will not be legally sold in the market.
GB/T 19606-2024 "Noise limits for household and similar electrical appliances" will officially come into effect on September 1, 2026, replacing the GB 19606-2024 standard.
The nature of the standard has changed from mandatory to recommended in this revision, but the detailed rules on noise testing methods in the mandatory standard GB 44498-2024 "Health technical specification for household and similar electrical appliances" fully adopt GB/T 19606-2024. Furthermore, the corresponding noise limits in GB/T 19606-2024 fully adopt the values specified in GB 44498-2024. The two are closely linked and jointly regulate the noise of household electrical appliances.

A wide range of applicable products has been expanded
GB/T 19606-2024 covers the noise limit requirements and test methods for 19 categories of household electrical appliances, adding 13 categories of products based on the old version of the standard. The specific differences in product categories are shown in the table below:
GB 19606 - 2004 old version | GB/T 19606 - 2024 new version |
refrigerator | Refrigeration equipment |
air conditioner | Room air conditioner |
washing machine | washing machine |
microwave oven | microwave oven |
range hood | range hood |
electric fan | electric fan |
/ | Waste food processor |
/ | electric shaver |
/ | Indoor heater |
/ | Humidifier |
/ | air purifier |
/ | vacuum cleaner |
/ | dishwasher |
/ | Drum dryer |
/ | Electric Massager |
/ | Electric food processing equipment |
/ | hair dryer |
/ | Dry cleaning robot |
/ | Water dispenser treatment device |
Detailed Explanation of Changes in Noise Limits and Testing Methods for 6 Types of Products in the New Standard
01
Changes in Limits and Test Methods for Refrigerating Appliances
(1) Changes in Limit Requirements:
GB 19606-2004 Old Version:

Requirements of the new version of GB/T 19606-2024 (citing GB 44498-2024):

Although the numerical noise limit remains unchanged, the classification boundary for product volume has increased from 250L to 300L, so the noise limit requirements for refrigeration appliances in the range of >250L and ≤300L have become stricter.
(2) Differences in Testing Methods:
Differentiating points | GB 19606-2004 old version | GB/T 19606-2024 New Edition |
Test envelope surface
| Simple rectangular envelope, with 4 measurement points around
| Select based on the dimensions and installation method of the prototype: • 9 measurement points on the centered rectangular envelope surface • 6 measurement points on the wall-side rectangular envelope surface (or 10 measurement points, depending on the dimensions) • 10 measurement points on the hemispherical envelope surface |
Test Status | Set to medium or moderately strong cold state | Refrigerator compartment 5℃, freezer compartment -22℃, measured temperature |
test cycle | Test after running for at least 30 minutes | 3 on-off cycles |
computational method | Note: The average sound pressure level is the arithmetic mean
| Note: The average sound pressure level is the logarithmic average
|
02
Changes in Limits and Test Methods for Air Conditioners
(1) Changes in limit requirements:
GB 19606-2004 Old Version:

GB/T 19606-2024 new version requirements (referencing GB 44498-2024) add limit requirements for sound power level:

Sound pressure level and sound power level are different parameters, which require special attention when labeling noise values. In addition, the new version has eliminated the 14~28kW classification, and the limit requirements within this range have become stricter.
(II) Differences in test methods:
The sound pressure level test method in the old version refers to GB/T 7725-2004, while the sound pressure level test method in the new version refers to GB/T 7725-2022. The new standard adds a sound power level test method (Annex A).
03
Changes in Limits and Test Methods for Washing Machines
(1) Changes in Limit Requirements:
GB 19606-2004 old version | New version requirements of GB/T 19606-2024 (referencing GB 44498-2024) |
Washing machine sound power level Washing: 62dB(A) Dehydration: 72dB(A) | Washing machine (including the washing part of a washer-dryer and a spin dryer) Washing: 62dB(A) Spinning (declared maximum spin speed ≤1200r/min): 72dB(A) Spinning (declared maximum spin speed >1200r/min): 76dB(A) |
(2) Differences in Testing Methods:
Differentiating points | GB 19606-2004 old version | GB/T 19606-2024 New Edition |
Test envelope surface
| Simple rectangular envelope, with 4 measurement points around
| 6 measurement points on the rectangular envelope surface against the wall
|
Test Status | Rated washing and dehydration condition Load: A combination of sheets, shirts, tablecloths, and handkerchiefs specified by the standard | Standard test program, maximum dehydration speed Load: Towel combination specified by the standard |
test cycle | Washing: No specific time specified Dehydration: Test after 3 minutes | Three standard procedures; if dehydration exceeds 3dB(A) in any two instances, three additional tests need to be added |
computational method | Note: The average sound pressure level is the arithmetic mean ![]() | Note: The average sound pressure level is the logarithmic average
|
04
Changes in Limits and Test Methods for Microwave Ovens
Differentiating points | GB 19606-2004 old version | GB/T 19606-2024 New Edition |
limit | Sound power level is 68dB(A) | Sound power level is 65dB(A) |
Test envelope surface | Centered placement, 5 measurement points (points 1-5 in the figure)
| Select based on the dimensions and installation method of the prototype: • 9 measurement points on the centered rectangular envelope surface • 6 measurement points on the wall-side rectangular envelope surface (or 10 measurement points, depending on the dimensions) • 10 measurement points on the hemispherical envelope surface |
Test Status | Normal load, the highest microwave power level or combination microwave oven is tested respectively while running after operating for 1 min at the highest microwave power level and the highest grill function level. | Standard test load, for microwave function and all possible combination functions, measurement should start 2 minutes after the appliance is started and end before the water boils |
05
Changes in Limits and Test Methods for Range Hoods
(1) Changes in limit requirements:
GB 19606-2004 Old Version:

Requirements of the new version of GB/T 19606-2024 (citing GB 44498-2024):

(2) Differences in Testing Methods:
Differentiating points | GB 19606-2004 old version | GB/T 19606-2024 New Edition |
Test envelope surface | Global Envelope Surface 4 Measurement Points
| 6 measurement points on the rectangular envelope surface against the wall
|
Test Status | Both the air inlet and outlet are in free space | Connect the outlet to a standard silencer pipe |
computational method | Note: The average sound pressure level is the arithmetic mean
| Note: The average sound pressure level is the logarithmic average
|
06
Changes in Limits and Test Methods for Electric Fans
(1) Changes in Limit Requirements
GB 19606-2004 Old Version:

Requirements of the new version of GB/T 19606-2024 (citing GB 44498-2024):

The limit values remain unchanged, and the new standard adds requirements for determining the noise limit values of oscillating fans and ceiling fans.
(2) Differences in Testing Methods:
Differentiating points | GB 19606-2004 old version | GB/T 19606-2024 New Edition |
Test envelope surface | 4 measurement points of hemispherical and global envelope surfaces
| The wall fan uses a hemispherical surface with 10 measurement points for wall-mounted installation. Other devices use a centrally positioned rectangular hexahedron with 9 measurement points.
|
computational method |
Note: Among the 4 measurement points of each electric fan, if the difference in sound pressure level between any two points is ≤5dB, the average sound pressure level can be calculated using the arithmetic mean; if the difference is >5dB, the logarithmic mean value shall be used for calculation. |
Note: The average sound pressure level is the logarithmic average |
New noise limit requirements for 13 categories of products
humidifier
New limit.

air purifier
New limit.

electric massager
New limit.

Drinking Water Treatment Device
New limit.

Other equipment requirements
GB/T 19606-2024 New Edition | Sound power level limit |
Waste food processor | 82 dB(A) |
electric shaver | 75 dB(A) |
Indoor heater | Thermal storage type 55 dB (A); Fan type 69 dB (A) |
vacuum cleaner | 86 dB(A) |
dishwasher | 58 dB(A) |
Drum dryer | 69 dB(A) |
Electric food processing equipment | 92 dB(A) |
hair dryer | ≤1500W 80 dB(A); 83dB |
Dry cleaning robot | 86 dB(A) |
Compliance Recommendations
GB/T 19606-2024 "Noise Limits for Household and Similar Electrical Appliances" specifies the noise limits, testing methods, and noise labeling requirements for household and similar electrical appliances, covering 19 major categories of household appliances. The standard specifies the market entry threshold, and products with excessive noise will not be legally sold in the market.
Jiayu Testing, as a professional third-party testing and certification service organization, has qualifications such as CMA, CNAS, CBTL, CCC, and has obtained laboratory accreditation from multiple authoritative certification institutions at home and abroad. It is equipped with advanced instruments and equipment, has a professional technical team with superb technical skills, rich industry service experience, and strong testing technology capabilities. It is proficient in various regulatory standards and specializes in providing one-stop testing and certification services for various electronic and electrical products (such as home appliances, wireless communication products, smart wearables, smart home products, information technology products, audio and video products, lighting products, spare parts products, etc.) to ensure that products meet relevant regulatory requirements. Welcome to contact us 400-9269-886!
Related News
Wechat Public
Account
Hotline
Hotline
Follow
The Public
Follow Us
- Back