The mandatory national standards for plugs and sockets, GB 1002-2024 "Types, basic parameters and dimensions of single-phase plugs and sockets for household and similar purposes" and GB 2099.7-2024 "Safety technical specifications for extension cords and sockets for household and similar purposes", will be implemented from August 1, 2025.
The mandatory national standards for plugs and sockets, GB 1002-2024 "Types, basic parameters and dimensions of single-phase plugs and sockets for household and similar purposes" and GB 2099.7-2024 "Safety technical specifications for extension cords and sockets for household and similar purposes", will be implemented from August 1, 2025, respectively replacing GB/T 2099.7-2015 and GB/T 1002-2021. The recommended national standards have been converted into mandatory national standards, and the safety of plugs and sockets has been upgraded.

PART 01
GB 1002-2024 "Types, basic parameters and dimensions of single-phase plugs and sockets for household and similar purposes"
01. The scope of application of the standard has been changed - the rated current has been increased to no more than 32A
| New Edition | Old Version |
| This document is applicable to single-phase plugs and sockets for household and similar purposes, with an AC frequency of 50 Hz, a rated voltage of 250V, and a rated current not exceeding 32A. | This document is applicable to single-phase plugs and sockets with an AC frequency of 50Hz, a rated voltage of 250V, and a rated current not exceeding 16A used in households and similar household environments. |

03. It is mandatory to have an insulation sheath with a plug
This standard mandates the addition of insulation sheaths to plugs to prevent users from directly contacting the metal pins of the plug during insertion and removal, thereby comprehensively preventing the risk of electric shock during the insertion and removal process.

For non detachable plugs or detachable plugs, and converters that comply with GBT 2099.3, the color of the insulation sheath is black, white, or gray.
For plugs of direct insertion devices, the color of the insulation sheath can be chosen by the manufacturer, but it cannot be yellow, green, or a combination of yellow and green.
04. Added measurement requirements for the distance between insulated sheathed pins and the edge of the plug
The requirement for the pin to be 6.5mm away from the edge of the plug: for products with insulation sheath, measure after peeling off the insulation sheath!
The height of the protruding part of the plug mating surface cannot exceed 0.5mm. Examples of "protrusions" include electrical parameters, trademarks, and other markings formed by injection molding on the plug mating surface, or other structures that may affect the appearance of the plug mating.


06. Added definition and assessment requirements for direct insertion equipment
The power plug and the device casing form an integral part of the device.
Note: Examples of direct insertion devices include razors with rechargeable batteries, night lights installed in power sockets, plug-in transformers, and power adapters.



08. A single plug cannot rotate axially
The individual pins of the plug should not undergo axial rotation that changes the type and position.
Note: Axial rotation, for example, by twisting the pins, changes the two parallel arranged pins of the plug in Figure 1 to the position form of the phase pole and neutral pole arrangement shown in Figure 3.

09. Add a new form of single-phase two pole ungrounded plug - "external eight character" two plug
This type of plug cannot be inserted into the socket of the grounding electrode driven protective door. 32A is not allowed to be ungrounded!

PART 02
GB 2099.7-2024 "Safety Technical Specification for Extension Line and Socket for Household and Similar Purposes"
01. Two new categories of outdoor sockets have been added
New electric bicycle extension cable charging socket: It is required to have safety functions such as waterproof and overcharge prevention, to avoid outdoor charging of electric bicycles encountering rainwater or accidental water immersion, leakage and short circuit, and to prevent overcharging from causing electrical fires.
New electric vehicle discharge socket: It is required to have waterproof, anti rolling, vibration and other safety functions to prevent electric vehicle discharge sockets from short circuiting due to water leakage, further improving equipment safety and stability. These measures can effectively prevent leakage short circuits caused by rainwater, water immersion, or accidental collisions, as well as electrical fires caused by overcharging, significantly improving the safety performance of the product.
02. Clarify the classification and usage of extension cord sockets for household and similar purposes
The classification and use of extension cord sockets are more clearly defined in the new national standard (GB 2099.7-2024). The products are classified into ordinary type, electric bicycle charging type, electric vehicle discharging type, furniture installation type, and winding device type, and it is strictly stipulated that ordinary extension cord sockets cannot be used for electric bicycle charging and must be marked with warning signs.
In terms of power limitation, the ordinary type is ≤ 4kW, the total power for electric vehicles is ≤ 8kW (requiring multiple socket combinations), the furniture installation type is ≤ 2.5kW, and the winding device is ≤ 1.5kW (flexible cable length ≤ 3m). These restrictions are aimed at preventing safety hazards caused by overload.
03. Waterproof and overcharge prevention function
Waterproof and overcharge prevention functions are particularly critical in the charging scenario of electric bicycles. The new national standard (GB 2099.7-2024) requires that the protection level of such sockets should be ≥ IP54 when not plugged in and ≥ IP55 when plugged in, and that products declared waterproof should undergo a salt spray test containing 1% NaCl solution. Functionally, it needs to have overcharge cutoff (power off within 180 minutes after the current drops to the set value) and 8-hour automatic power-off mechanism to reduce the risk of fire from the source. In terms of mechanical strength, the socket needs to pass 16 drops from a height of 1.5 meters and a compression test with a pressure of 650 N to ensure that the shell is not broken and functions properly.
04. Overload protection and adaptability to high and low temperatures
The new national standard (GB 2099.7-2024) has stricter requirements for overload protection and current matching. The rated current of a regular extension cord socket plug must meet two conditions simultaneously: not less than the current of a single socket, and not exceeding the rated current of a fixed wiring socket (whichever is smaller). For example, for a socket with 3 10A sockets, if the fixed wiring socket is 16A, the rated current of the plug only needs to be ≥ 16A.
The new national standard also requires that ordinary extension line sockets (including mobile sockets) with 4 or more positions must be equipped with overcurrent protection devices, which must comply with the full series standards of GB/T 17701, GB/T 14536, and GB/T 13539. The protective device should be able to cut off the main circuit power supply, and at least cut off the live wire (L) for sockets with grounding contacts.
Environmental adaptability testing covers extreme usage scenarios. The electric bicycle charging socket needs to be powered on for 2 hours in environments of -30 ℃ and 55 ℃ and function normally. The plug of the direct insertion device needs to pass the roller drop test (such as ≤ 100g product drop 100 times). These experiments simulate harsh outdoor conditions to ensure that the product can still be safely used in low temperatures, high temperatures, or accidental drops.
PART 03
Version change requirements and compliance recommendations
Starting from August 1, 2025, the new version of the standard/implementation rules for certification should be adopted and a new version of the standard certification certificate should be issued, and the old version certificate will no longer be issued.
For products that have been certified according to the old version of the standard, the holder of the old version of the standard certification certificate should promptly submit an application to convert to the new version of the standard certification certificate, and complete the product confirmation and certificate replacement according to the new version of the standard in accordance with the relevant resolutions of TC07 after the implementation date of the standard and before the end of the first tracking inspection. The conversion of all old version standard certification certificates should be completed no later than August 1, 2026; If the certification is not completed within the deadline, the old version of the standard certification certificate will be suspended. Certification certificates that have not been converted before November 1, 2026 will have their old version of the standard certification revoked.
For plug and converter products that comply with the requirements of GB 1002-2024 standard, according to the relevant provisions of the standard implementation, the work of adding insulation sheath to live plugs should be completed no later than August 1, 2027. If the work is not completed within the deadline, the relevant product certification certificate will be suspended. If the work of adding insulation sheath to live plugs is not completed by November 1, 2027, the relevant product certification certificate will be revoked.
As a professional third-party testing and certification service organization, Jiayu Testing has a professional testing technology team, equipped with advanced instruments and equipment, proficient in various regulatory standards, and provides professional testing and analysis services for various electrical accessory products and other component products to ensure that the products meet relevant regulatory requirements. Welcome to contact us at 400-9269-886!