Guidelines for CCC Version Replacement of Home Appliances (V): Interpretation of GB/T 4706.23-2024 CCC Version Replacement Requirements for Indoor Heaters
Time:
2026-02-02
Starting from August 1, 2026, the GB/T 4706 series of 3C safety standards for household appliances will be mandatory. During the transition period, enterprises can independently choose to conduct product certification according to the new or old version standards. This article mainly focuses on the special requirements of GB/T 4706.23-2024 indoor heaters, combined with the general requirements of GB/T 4706.1-2024, and provides a detailed interpretation of the relevant requirements for CCC version change of indoor heaters.
The 3C safety standards for household appliances are updated! Starting from August 1, 2026, the GB/T 4706 series standards will be mandatory. During the transition period, enterprises can independently choose to conduct product certification according to the new or old version standards.
This article mainly focuses on the main content of the new standard GB/T 4706.23-2024 "Safety of household and similar electrical appliances - Part 23: Special requirements for indoor heaters", and combines GB/T 4706.1-2024 "Safety of household and similar electrical appliances - Part 1: General requirements" to provide a detailed interpretation of the relevant requirements for the CCC version change of indoor heaters.
Household Appliances CCC Certification National Accreditation Laboratory
Jiayu Testing is a nationally recognized laboratory for CCC certification of household appliances, and also one of the first laboratories that can issue testing reports for the replacement of 3C standards for household appliances. It can help household appliance enterprises quickly and efficiently obtain 3C certification certificates. Welcome to contact us at 400-9269-886!
GB/T 4706.23 Notice for CCC Version Replacement of Indoor Heaters
01. Scope of applicable products
This document is applicable to indoor heaters for household and similar purposes. The rated voltage of single-phase appliances shall not exceed 250V; the rated voltage of other appliances shall not exceed 480V.
Example of appliance: convection heater; Fan type heater; Heaters used in greenhouses; Liquid filled radiator; Plate heater; Radiant heater; Tubular heater; Ceiling mounted heating appliances; Car heater.
This document also relates to the safety of electric heaters used to heat the driver's and passenger compartments of motor vehicles in a stationary state, with a rated voltage not exceeding 250V.
Appliances that are not intended for general household use but may still pose a danger to the public, such as indoor heaters intended for use by non professionals in shops, light industrial sites, and farms, are also within the scope of this document.

(Partial product examples)
02. Version change process
Data preparation;
Submit applications online;
Sample testing;
Report review;
Certificate issuance;
Annual supervision;
03. Provide information
Certificates and all original reports;
Business license;
Explanation of Differences;
Declaration of nameplate and nameplate material;
Product manual;
List of components and non-metallic materials;
Electrical schematic diagram, etc.
04. Inspection requirements
Two main inspection models and one coverage model.
05. Certification cycle
Expected to take around 15 working days.
Main technical changes of indoor heaters in GB/T 4706.23
01. The new version of standard GB/T 4706.23-2024 adds the scope of application of the standard: "Ceiling mounted lamp heating appliances" and "vehicle heaters" are included in the scope of application of the standard.
02. Chapter 7 of the new standard GB/T 4706.23-2024 adds different gear identification methods for indoor heater switches and control devices:
The different positions of switches and control devices on indoor heaters should be represented by numbers, letters, or other visual means. This requirement also applies to switches that are part of the controller.
When the heater is in its expected use state, the opening position of the switch and control device should be clearly visible to the user.
03. The new version of standard GB/T 4706.23-2024 has added temperature rise limit requirements for ventilation openings and air flaps, refined the classification of Table 101 and added temperature rise limits, and added temperature rise requirements for three types of heaters.
04. New tests have been added for abnormal operation of ceiling mounted lamp heating appliances, vehicle heaters, and fan room heaters. Please refer to Chapter (Section) 19.115, 19.116, and 19.117 for details.
05. The main non compliant high-frequency points of indoor heaters are exceeding the temperature rise limit in Chapter 11 and failing the 15 ° tilt test in Chapter 20.1.
Suggestions for rectification of unqualified temperature rise: optimize the heat dissipation structure, adjust the operating temperature or installation position of the thermostat;
15 ° dumping unqualified rectification suggestion: lower the center of gravity of the product and increase the bottom contact area.
Compliance Service
As a professional third-party testing and certification service organization, Jiayu Testing has been recognized by CNAS, CMA, and CBTL. It is equipped with a skilled professional technical team, rich industry service experience, and strong testing technology capabilities. Jiayu Testing is a nationally recognized laboratory for household appliance CCC certification, and is also one of the first laboratories that can issue new 3C standard replacement testing reports for household appliances. It specializes in providing one-stop 3C certification services for various household appliance products, which can help household appliance enterprises quickly and efficiently obtain 3C certification certificates, ensuring that product quality and safety meet national standard requirements. Welcome to contact us at 400-9269-886!