Amendment to the Pollutant Discharge Standards for Urban Sewage Treatment Plants GB 18918-2002, to be implemented on March 1, 2026


Time:

2026-02-27

The revised version of the "Pollutant Discharge Standards for Urban Sewage Treatment Plants" (GB 18918-2002) will be implemented from March 1, 2026.

The amendment to the "Pollutant Discharge Standards for Urban Sewage Treatment Plants" (GB 18918-2002) will be implemented from March 1, 2026, and will modify, adjust, and add 12 contents such as "Water Pollutant Discharge Standards" and "Air Pollutant Discharge Standards".

 


The Ministry of Ecology and Environment and the State Administration for Market Regulation jointly issued the "Pollutant Discharge Standards for Urban Sewage Treatment Plants" (GB 18918-2002) (hereinafter referred to as the "Amendment"). The responsible persons from the Water Ecological Environment Department of the Ministry of Ecology and Environment and the Urban Construction Department of the Ministry of Housing and Urban Rural Development answered questions from reporters regarding the background, basic principles, and main contents of the revised form.

 

Q: What is the background for the issuance of the amendment form?

Answer: Urban sewage treatment plants are not only important pollution control facilities, but also key units for water pollutant discharge. Since the implementation of the "Pollutant Discharge Standards for Urban Sewage Treatment Plants" (GB 18918-2002), it has played an important role in controlling the discharge of pollutants from urban sewage treatment plants, protecting and improving the quality of the ecological environment. During the implementation of the standard, it was found that the daily average requirement could not scientifically support the determination of instantaneous values exceeding the standard, and the limit of fecal coliforms in the first level A standard was not precise enough for non recycled water, pH、 The use of daily averages for the three indicators of chromaticity and fecal coliform count cannot effectively prevent problems such as instantaneous impact. Therefore, in order to further strengthen the accuracy and scientificity of standard technical content, and improve the coordination and compatibility between standards and regulatory enforcement systems, the Ministry of Ecology and Environment has organized the compilation and jointly issued a modification form with the State Administration for Market Regulation.

 

Q: What are the main contents of the modification order?

Answer: The main contents of the modification form include:

One is to add four instantaneous values of major water pollutants. Focusing on solving the prominent problems faced in the supervision and law enforcement of urban sewage treatment plants, based on scientific statistical analysis, we have added instantaneous value requirements for chemical oxygen demand, ammonia nitrogen, total nitrogen, and total phosphorus pollutants that are slightly higher than the daily average, which is more realistic.

The second is to adjust the daily average values of pH, chromaticity, and fecal coliforms to instantaneous values. These three indicators are enforced using daily averages, which cannot effectively prevent the impact of instantaneous high values on environmental water bodies. Therefore, based on the analysis and testing characteristics of the three indicators, combined with international practices and China's regulatory reality, the modification form adjusts the limit types of the three indicators from daily averages to instantaneous values.

The third is to differentiate the discharge direction of effluent and refine the first level A limit of fecal coliforms. The first level A limit for fecal coliforms in the current standards is mainly set for the requirements of reuse water. The limit for effluent discharged into environmental water bodies is too strict, which may also lead to excessive use of disinfectants, thereby causing harm to the water ecological environment. The modification order adjusts the limit of fecal coliforms in non reusable effluent to 10000 MPN/L, which is the same as the Class III water quality limit for surface water. This not only ensures the quality of the water environment, but also avoids the secondary impact of excessive disinfection on the aquatic ecological environment, and reduces the disinfection cost of sewage treatment plants.

The fourth is other related modifications. Improve implementation and supervision regulations, clarify that both instantaneous values and daily average values can be used as the basis for determining and enforcing regulations on exceeding standards, and exceeding any limit value is considered as exceeding the standard; According to the Technical Specifications for Wastewater Monitoring (HJ 91.1-2019), the sampling and monitoring requirements for daily mean and instantaneous values are specified; Adjust the applicable requirements for sewage treatment plants in established towns to make the requirements of smaller scale sewage treatment plants more in line with reality.

 

Q: How will urban sewage treatment plants carry out self-monitoring after the implementation of the modification order?

Answer: The amendment stipulates that urban sewage treatment plants should conduct self-monitoring in accordance with the "Technical Guidelines for Self Monitoring of Pollutant Discharge Units in Water Treatment" (HJ 1083) and other regulations, keep original monitoring records, and publicly disclose monitoring results.

The frequency requirement for self-monitoring is a common concern for urban sewage treatment plants, and HJ 1083 specifies that the flow rate pH、 Water temperature, chemical oxygen demand, ammonia nitrogen, total nitrogen, total phosphorus and other pollutants require automatic monitoring (including daily monitoring before the implementation of the technical specifications for automatic monitoring of total nitrogen); The monitoring frequency for suspended solids, chromaticity, five-day biochemical oxygen demand, animal and vegetable oils, petroleum, anionic surfactants, and fecal coliforms is once a month (sewage treatment plant treatment capacity ≥ 20000 m ³/d) or once a quarter (treatment capacity<20000 m ³/d); The monitoring frequency for total cadmium, total chromium, total mercury, total lead, total arsenic, and hexavalent chromium is once every quarter (processing capacity ≥ 20000 m ³/d) or once every six months (processing capacity<20000 m ³/d); The monitoring frequency for other pollutants is once every six months or every two years.

For each manual monitoring, the modification form also provides specific regulations: measure the daily average, sample the frequency according to HJ 91.1, and analyze and test the mixed samples; According to HJ 91.1, for items that cannot be measured in mixed samples, analysis and testing should be conducted on each sample taken within 24 hours, and the arithmetic mean should be calculated. At the same time, the amendment also stipulates that instantaneous values should be measured in accordance with HJ 91.1, and instantaneous water samples should be collected and analyzed for testing.

 

Q: How to determine if the modification order exceeds the standard after implementation?

Answer: For the four pollutants of chemical oxygen demand, ammonia nitrogen, total nitrogen, and total phosphorus, adding instantaneous values while retaining the daily average regulations is equivalent to having two standard lines, exceeding either one is considered excessive, further improving regulatory efficiency. For pH, chromaticity, and fecal coliform count, they are judged as exceeding the standard based on instantaneous values. For other pollutants, the determination of exceeding the standard is still based on the daily average regulation.


As a professional third-party testing and certification service organization, Jiayu Testing has qualifications such as CMA, CNAS, and occupational health technical service institutions. In the field of environmental testing, it currently has more than 1000 CMA testing parameters, covering water and wastewater, air and exhaust gas, soil and sediment, noise and vibration, and solid waste toxicity identification. The laboratory is built and managed strictly in accordance with standards, equipped with advanced instruments and equipment, and has a professional technical team with superb skills. It has rich industry service experience and strong testing technology capabilities. Based on the principles of objectivity and fairness, it provides authoritative testing reports with legal effect to the society, and provides full chain environmental risk management support for enterprises and regulatory departments. Welcome to contact us at 400-9269-886!

 