Mandatory implementation on March 1, 2026! GB 30720-2025 "Energy Efficiency Limits and Grades for Gas Stoves"
Time:
2026-02-27
The mandatory national standard GB 30720-2025 "Energy Efficiency Limits and Grades for Gas Stoves" will be officially implemented on March 1, 2026. The new national standard comprehensively replaces the two energy efficiency standards for household and commercial gas stoves, and divides the energy efficiency levels into three levels, raising the energy efficiency entry threshold for each level.
The mandatory national standard GB 30720-2025 "Energy Efficiency Limits and Grades for Gas Stoves" will be officially implemented on March 1, 2026. Fully replace the two energy efficiency standards for household and commercial gas stoves, GB 30720-2014 "Energy Efficiency Limits and Grades for Household Gas Stoves" and GB 30531-2014 "Energy Efficiency Limits and Grades for Commercial Gas Stoves".
Main technological changes
1. Expanded scope of application
Merge the standards for household gas stoves and commercial gas stoves, and standardize their management. The scope of application is as follows:
Household gas stoves: household gas stoves and integrated stoves that use urban gas and have a rated heat load of no more than 5.23kW.
Commercial gas stoves: stir fry stoves with a rated heat load not exceeding 60kW, large pot stoves with a rated heat load not exceeding 80kW, water tank and steam generator steamers with a rated heat load not exceeding 80kW.
2. Energy efficiency threshold raised
The new national standard divides energy efficiency levels into three levels, raising the energy efficiency admission threshold for each level, and the increase in energy efficiency limit values is particularly significant.
Household gas stoves: Embedded/desktop stoves have increased their first level energy efficiency and thermal efficiency from the old standard of 63% to 70%, second level energy efficiency to 64%, and third level energy efficiency to 59%; The first level energy efficiency and thermal efficiency of the integrated stove are 66%, 62% for the second level, and 56% for the third level.
Commercial gas stoves: Clearly define energy efficiency indicators for different categories, with a first level energy efficiency of 45% for stir fry stoves, 65% for large pot stoves, 91% for steamers, and 94% for steam generators.
3. Delete 'energy-saving evaluation value'
Simplify the evaluation system, delete the "energy-saving evaluation value", and focus on the core indicator control of "energy efficiency limit value (level 3)".
4. Optimization of testing methods
Domestic gas appliances
The test conditions and methods for household gas stoves shall be conducted in accordance with GB16410.
During the integrated stove thermal efficiency test, the fan should be set to the highest speed range, and the exhaust pipe should be the shortest or rated length declared by the manufacturer.
When the fan is operating continuously at rated voltage, rated frequency, static pressure of 0Pa, and maximum speed, it should not automatically switch to other speed gears.
Commercial gas stove
The thermal efficiency test method for steam generators and steam generating steam boxes shall be conducted in accordance with Appendix A.
The test conditions and methods for the water tank steamer, stir fry stove, and large pot stove shall be conducted in accordance with GB35848.

Energy efficiency grade of household gas stoves
The energy efficiency level of household gas stoves is divided into three levels, with level 1 having the highest energy efficiency. The thermal efficiency values of each level should not be lower than those specified in Table 1.
Table 1 Energy Efficiency Grades of Household Gas Stoves
| Gas stove type | Thermal efficiency/% | ||
| Level 1 | Level 2 | Level 3 | |
| Embedded/Desktop | 70 | 64 | 59 |
| integrated | 66 | 62 | 56 |
Energy efficiency grade of commercial gas stoves
The energy efficiency level of commercial gas stoves is divided into three levels, with level 1 having the highest energy efficiency. The thermal efficiency values of each level should not be lower than those specified in Table 2.
Table 2 Energy Efficiency Grades of Commercial Gas Stoves
| Gas stove type | Thermal efficiency/% | ||
| Level 1 | Level 2 | Level 3 | |
| Stir fry stove | 45 | 35 | 25 |
| Large pot stove | 65 | 55 | 45 |
| steamer | 91 | 80 | 70 |
| steam generator | 94 | 89 | 80 |
Starting from March 1, 2026, the production and sale of household/commercial gas stoves that do not meet Level 3 energy efficiency standards will be prohibited.
As a professional third-party testing and certification service organization, Jiayu Testing has qualifications such as CMA, CNAS, CBTL, CCC, etc. It is also a laboratory for energy efficiency labeling registration and testing in China. It has a professional testing technology team, equipped with advanced instruments and equipment, proficient in various regulations and standards, and can provide China energy efficiency labeling testing and filing services for various electronic and electrical products. If your product requires safety and energy efficiency certification, please feel free to contact us at 400-9269-886!