Services: Electrical testing and certification, environmental or chemical testing

Guidelines for CCC Version Replacement of Home Appliances (VIII): Interpretation of CCC Version Replacement Requirements for Heat Pumps, Air Conditioners, and Dehumidifiers (GB/T 4706.32-2024)


Time:

2026-05-06

Starting from August 1, 2026, the GB/T 4706 series of 3C safety standards for household appliances will be mandatory. This article mainly focuses on the special requirements of GB/T 4706.32-2024, combined with the general requirements of GB/T 4706.1-2024, and specifically interprets the relevant requirements for CCC version replacement of heat pumps, air conditioners, and dehumidifiers.

Starting from August 1, 2026, the CCC safety standards for household appliances GB/T 4706 series standards will be mandatory. During the transition period, enterprises can independently choose to conduct product certification according to the new or old version standards.

 

This article mainly focuses on the main content of the new standard GB/T 4706.32-2024 "Safety of household and similar electrical appliances - Part 32: Special requirements for heat pumps, air conditioners, and dehumidifiers", and combines GB/T 4706.1-2024 "Safety of household and similar electrical appliances - Part 1: General requirements" to interpret the relevant requirements for CCC version change of heat pumps, air conditioners, and dehumidifiers.

 

 

 

National Accredited Laboratory for CCC Certification of Household Appliances

Jiayu Testing is a nationally recognized laboratory for CCC certification of household appliances, and also one of the first laboratories that can issue testing reports for the replacement of 3C standards for household appliances. It can help household appliance enterprises quickly and efficiently obtain 3C certification certificates. Welcome to contact us at 400-9269-886!

 

 

GB/T 4706.32 Notice on CCC Version Change for Heat Pumps, Air Conditioners and Dehumidifiers

 

 

01

 

Applicable product range

 

This document specifies the safety requirements for household and similar use heat pumps, air conditioners, and dehumidifiers.

This document applies to single-phase appliances with a maximum rated voltage not exceeding 300V, other appliances with a maximum rated voltage not exceeding 600V, heat pumps, domestic hot water heat pumps and air conditioners equipped with motor compressor and circulating fan coil units, dehumidifiers (with or without motor compressor), thermoelectric heat pumps and some units.

Appliances that are not intended for household use but still pose a danger to the public, such as those used by non professionals in shops, light industry, and farms, are also within the scope of this document.

The above-mentioned equipment may consist of components produced by one or more factories. If multiple components are provided and these individual components need to be used together, the technical requirements of this document are based on the use of assembled components.

(Partial product examples)

 

02

 

Version Change Process

 

Data preparation;

Submit applications online;

Sample testing;

Report review;

Certificate issuance;

Annual supervision;

 

03

 

Provide materials

 

Certificates and all original reports;

Business license;

Explanation of Differences;

Declaration of nameplate and nameplate material;

Product manual;

List of components and non-metallic materials;

Electrical schematic diagram, etc.

 

04

 

Submission Requirements

 

2 units of the main inspection model, 1 unit of each covered model.

 

05

 

Certification cycle

 

It is estimated to take around 15 working days.

 

 

Main technical changes of GB/T 4706.32 heat pumps, air conditioners and dehumidifiers

 

 

01

Appliances using flammable refrigerants shall be marked with a flame symbol containing the safety classification in accordance with ISO 817.

 

1.警告.png

Warning: Combustible Materials

 

02

For appliances with flammable refrigerants, it is necessary to test the arcs and sparks generated by electrical components, such as relays requiring explosion-proof certification.

 

03

According to the control requirements of the Kigali Amendment and in combination with the maturity of industry substitution technologies, HFC reduction and substitution will be implemented in different industries and stages.

 

Starting from January 1, 2029, it is prohibited to produce household air conditioners (room air conditioners) filled with refrigerants with a global warming potential (GWP) greater than 750 for domestic sales, except for household multi split air conditioning (heat pump) units.


Interpretation: Ban GWP>750 → R134a, R410A are out, R32 dominates

 

04

High-frequency non-compliance points: The indoor unit panel of the air conditioning cabinet is detachable, and the fan lacks a protective cover. This fails to meet the requirements of Clause 20.2 in GB/T 4706.1-2024.

 

05

High-frequency non-compliance point: The temperature sensing probe lacks sufficient protection and fails to meet the requirements for Class II construction as stipulated in Clause 8.2 of GB/T 4706.1-2024.

 

 

 

Compliance Services

 

 

Jiayu Testing, as a professional third-party testing and certification service provider, is accredited by CNAS, CMA, and CBTL. Equipped with a skilled technical team, extensive industry service experience, and robust testing capabilities, Jiayu Testing is a nationally recognized laboratory for household appliance CCC certification and among the first batch of labs authorized to issue test reports under the new CCC standards for appliances. We specialize in providing one-stop CCC certification services for various household appliances, helping manufacturers obtain CCC certificates quickly and efficiently while ensuring product quality and safety comply with national standards. Contact us at 400-9269-886 

 